Ekhwesi's BEC23(09) range of prepayment meters offer a cost effective method of metering loads up to a maximum of 80A.
In addition, the meter consists of a two-part housing being a wallbase and the active meter. This configuration allows for the pre-installation of the wallbase and the ability to remove the meter for maintenance, without disconnecting the supply.
Description | Value |
---|---|
Voltage ratings
|
220VAC - 240VAC 50Hz |
Current ratings
|
5A80A20mA25mA (Earth leakage only)UC2 |
Nominal power consumption |
1.6W / 9VA |
Accuracy |
Class 1 and 2 (maintained throughout life cycle of product) |
Over voltage rating |
420VAC for 48 hours |
Short circuit rating |
Short-circuit withstand 2.5kA |
Protection |
Power overload Current overload Thermal Over / under voltage Line / load reversal |
Environmental
|
-10°C to +55°C -25°C to +70°C 95% non-condensing PL - IP54 30V/m |
Status indicators |
Rate LED (1000 pulses / kWh) |
Installation
|
Common wallbaseDouble insulation |
Terminals
|
Live: Bus bars Neutral: Bus bars |
Interrogation
|
Type A (direct probe) |
Security
|
Provision for lead seals or wire seals Plastic seals Load disconnection on tamper detection |
Standards |
IEC 62051-1 IEC 62052-11 IEC 62053-21 IEC 62055-31 IEC 62055-41 IEC 62055-51 IEC 62055-52 SANS 1524-4 SANS 15417 STS 101-1 STS 201-15.1.0 DSP 34-749 DSP 34-1635 RES/RR/00/11740 SANS 1524-1-1 SANS 1524-1-2 OHSAS 18001 ISO 14001 ISO 9001 SANS 1524-1 |
Packaging
|
Wallbase 10 4.2kg |
Packaging
|
Meter 5 3.9kg |
Packaging
|
Meter and Wallbase 5 8.7kg |
Code | Description |
---|---|
#000# |
Dispenser test (STSO) |
#001# |
Load switch test (STS1) |
#002# |
Display test (STS2) |
#003# |
Input test device (STS6) |
#004# |
Accumulated energy consumed - MTTD (STS3) |
#005# |
Key revision and key type (STS4) |
#006# |
Tariff index (STS5) |
#007# |
Maximum power limit (STS7) |
#008# |
Tamper status (STS8) |
#009# |
Available credit |
#010# |
Phase unbalance (STS11) |
#011# - #029# |
STS reserved |
Code | Description |
---|---|
12754194144864505970 |
Activate Prepaid Electricity Meter |
#030# |
Retrieve SGC |
#200# |
Value of last credit token entered |
#201# |
ID of last credit token entered |
#202# |
Value of 2nd last credit token entered |
#203# |
ID of 2nd last credit token entered |
#204# |
Value of 3rd last credit token entered |
#205# |
ID of 3nd last credit token entered |
#206# |
Value of 4th last credit token entered |
#207# |
ID of 4th last credit token entered |
#208# |
Value of 5th last credit token entered |
#209# |
ID of 5th last credit token entered |
#210# - #248# |
Not used: value of credit token entered (6th - 25th tokens) |
#211# - #249# |
Not used: value of credit token entered (6th - 25th tokens) |
#251# |
Most recent token (Class, subclass, 20 digits, value) |
#252# |
2nd most recent token (Class, subclass, 20 digits, value) |
#253# |
3rd most recent token (Class, subclass, 20 digits, value) |
#254# |
4th most recent token (Class, subclass, 20 digits, value) |
#255# |
5th most recent token (Class, subclass, 20 digits, value) |
#256# |
6th most recent token (Class, subclass, 20 digits, value) |
#257# |
7th most recent token (Class, subclass, 20 digits, value) |
#258# |
8th most recent token (Class, subclass, 20 digits, value) |
#259# |
9th most recent token (Class, subclass, 20 digits, value) |
#260# |
10th most recent token (Class, subclass, 20 digits, value) |
#261# - #270# |
Not used |
#271# |
Estimated average daily and 30 day consumption |
#272# |
Last hour, 24 hour and 30 day consumption |
#273# |
Number of supply interruptions |
#274# |
Number of tamper detections |
#275# |
Lost communications counter |
#276# |
Eeprom memory data dump |
#277# |
Active load restriction duration and value |
#278# - #299# |
Not used |
Code | Description |
---|---|
#050# |
Instantaneous power (STS9) |
#051# |
GPS coordinates |
#052# - #069# |
STS reserved |
#070# |
Power consumption per phase |
#071# |
Current consumption per phase |
#072# |
Average voltage per phase |
#073# |
Reason for last disconnect |
#074# |
Time remaining till zero credit |
#075# |
RF signal strenth |
#076# |
User total consumption to date |
#077# |
Total user credit entered |
#078# |
STS token result |
#079# |
Manual reconnect |
#080# |
UIU reset |
#081# |
Display UIU refresh interval |
#082# |
Meter tamper switch status |
#083# |
Not used |
#084# |
Last post paid / prepaid tenancy change MTTD register |
#085# |
Manual disconnect |
#086# |
Reactive power and power factor |
#087# |
Display consumption counter |
#088# |
Currently active load limit value |
#089# - #099# |
Not used |